0 E N V I R O N M E N T A L M O N I T O R S E R V I C E , I N C . 09/ 15/2 0 1 1 R EV - 1 6 Model 1304 Installation and Operation Manual 

Página 2 - Warnings

9 Section 1 SYSTEM DESCRIPTION The Model 1304 Opacity Monitor provides continuous, low maintenance, precision measurement of opacity and optical dens

Página 3

10 PRINCIPLE OF OPERATION Normal mode of operation The Dual beam measurement system has a stack mounted Transmissometer sensor system consists of an

Página 4

11 Span Filter out: Span Filter in: Zero Reflector out: Zero Reflector in: RD MD Span Filter Zero Reflector Main Lamp TTL Bulls-eye Projec

Página 5 - Table of Contents

12 1304 OPACITY SPECIFICATIONS Design and performance: Meets or Exceeds PS-1 Revised and ASTM D6216-03 Peak and Mean Spectral Response Photopic; 515

Página 6

13 Enclosure NEMA 4 watertight enclosure Path Length 2 to 15 feet, 0.6 to 4.6 meters. Longer available Optical System Double Pass Light Source Aging

Página 7 - PO Box 4340

14 Section 2 INSTALLATION CONSIDERATIONS Choose an installation site The primary considerations for choosing a site for the Model 1304 are

Página 8 - Customer service

15 Alignment of stack flanges Stack flange alignment is shown on Drawing EMS-1001 and EMS 1002, and is the first step in successful

Página 9

16 Reading Analog output Block Addresses: 0% to 100% instantaneous opacity = 40150 (integer) (xx.xx), 0% to 100% average opacity = 40151

Página 10 - Section 1

17 Changing communication settings: Press EDIT (ESC) button, Scroll down EDIT  to COM MENU, press ENTER, at COM PORT press ENTER set

Página 11 - Normal mode of operation

18 MOUNTING THE AIR PLENUM AND WEATHER COVERS WARNING! Control unit, Transceiver & Retro serial numbers must match. After the installation site h

Página 12

1 Ship to: ENVIRONMENTAL MONITOR SERVICE 87 Gypsy Lane Meriden, CT. 06450 Phone 203.935.0102 ext 14 Fax 203.634.6663 E-mail: service@emsct

Página 13 - 1304 OPACITY SPECIFICATIONS

19 Transceiver and retro reflector assembly 1. Attach the Transceiver and Retro reflector to the air plenum assembly by placing them on the hi

Página 14

20 Beam alignment procedure Note: Alignment can not be done unless the power is applied to the stack mounted service module. The control unit does

Página 15 - Section 2

21 Air flow switch If you have an airflow alarm when the system is powered check the airflow switch. With the blower running and the source under nor

Página 16 - Sample area

22 LtLxOPLR Section 3 BEFORE START UP You must complete the following before start up is attempted. 1. Measure and record flange -to-flange distanc

Página 17 - Writing:

23 START UP SERVICE Environmental Monitor Service, Inc. is available to assist you, call our service department at (203) 935-0102 or fax (203) 634-66

Página 18

24 ZERO/SPAN CALIBRATION CHECK The zero calibration has been set at the factory by placing the instrument on an optical bench using the flange-to-fla

Página 19

25 Section 4 INSTRUMENT OPERATIONS AND ADJUSTMENTS Overview of the systems operation The Model 1304 Opacity monitor system consists of transceiver, r

Página 20

26 Control unit manual controls ACK - Acknowledges fault alarms and displays the fault message. DIS - Changes display each time it is pressed; Opacit

Página 21 - Adjusting bolts

27 4-20mA outputs Reference Drawing # 1131 The Model EMS1304 comes with two 4-20mA outputs. The ranges are set during final test to the information

Página 22 - Control unit

28 Auto cal timer Adjustment Under the flip down door, press the EDIT (ESC) button (the red Edit (ESC) LED will light). The message display will

Página 23 - Section 3

2 1. Limited Warranty a) Warranty. i) Except as otherwise provided herein, Seller warrants to Buyer that the Products sold to Buyer are, at the

Página 24 - QUICK MENU. Press

29 Service module The service module is used to pass signals to and from the transceiver and control unit, display opacity via digital meter, initiat

Página 25

30 Section 5 AJUSTMENTS Clear on stack zero and span calibration A clear stack condition must exist to perform this calibration. Power must hav

Página 26 - Section 4

31 3. Place the Opacity/ T2 switch on the service module in the Opacity position to observe the correlated opacity on the digital display. 4. Swing

Página 27 - Alarm Time Delay Adjustment

32 3. This completes the calibration. Off stack zero calibration This procedure may be used if: A clear stack condition is not possible and the zero

Página 28 - 4-20mA outputs

33 Section 6 USING THE ON LINE ZERO REFLECTOR (OPTION) The "Micro-turn" 200 on - line test and audit system P/N 1232 may be used for:  Op

Página 29 - Disable internal cal timer

34 2100*1001115.02OPOpM Where: OP1 = Standard filter Value in % M2 = OPLR for your instrument OP2 = Standard Filter valu

Página 30

35 Course adjustments 1. Opacity is below zero and you can not reach zero after you have turned the adjustment knob as far as it will go into the Mi

Página 31 - Section 5

36 Filter certification QA/QC testing by EMS of the filters at an interval of not more than 6 months is recommended. Filter certifi

Página 32 - Span filter VALUE

37 Section 7 PREVENTIVE/CORRECTIVE MAINTENANCE Preventive/corrective maintenance schedule Daily: Check Zero/Span marks are within specification (+/-

Página 33 - Off stack zero calibration

38 Yearly: Clear stack or off stack zero All quarterly checks Remove transceiver and retro, clean air plenum Replace any worn hoses and gaskets Check

Página 34 - Section 6

3 e) Software and Firmware Products. The sole and exclusive warranty applicable to software and firmware products provided by Seller for use with a

Página 35

39 Control unit preventive maintenance Preventive maintenance consists of cleaning the instrument regularly and inspecting it occasionally for broken

Página 36 - Micro-turn parts list

40 Trouble Shooting Problem Possible Cause Remedy Control unit reads 100%, both bargraphs are blinking, Alarm LED is on, Fault message T2 4-20mA lost

Página 37 - Filter certification

41 Trouble shooting -continued Problem Possible Cause Remedy Maintenance Mode message Maintenance switch or maintenance function is on 1- Control uni

Página 38 - Section 7

42 SPARE PARTS Level 1 - General maintenance supplies recommended for all users. Level 2 - Back up critical printed circuit boards and parts suggest

Página 39

43 Qty as needed 1366 Spare Model 1304 control unit, service module, transceiver & retro 3-15 Ft. 1 per plant 1234 Opacity test stands for s

Página 40

44 Section 8 DRAWINGS

Página 41 - Trouble Shooting

45 EMS 1001 - Mounting under 6‘ STACK

Página 42 - Trouble shooting -continued

46 EMS 1002 - Mounting over 6’ stack

Página 43

47 EMS 1024 - Air purge/Weather cover mech Installation

Página 44

48 EMS 1078 - PANEL cut out for 1304 control unit

Página 45 - Section 8

4 Table of Contents Guidelines for user safety and equipment protection 1 Warnings 1 Warrantee Registration 6 CCuussttoommeerr sseerrvviiccee 77

Página 46

49 EMS 1079 -1304 control unit dimensions

Página 47

50 EMS 1077 - Terminal identification 1304 control unit

Página 48

51 EMS 1131 -1304 with recorder system wiring

Página 49

52 PURGE BLOWER ELECTRICAL AND PRESSURE INFORMATION Single Phase 110VAC 50/60Hz 220VAC 50/60Hz Start Amps 9.0 4.5 Run Amps 4.5-5.7 2.2-2.8 H.P. 0.5

Página 50

53 EMS1101 - Sht 1 of 3 Dual Blower system wiring

Página 51

54 EMS 1101 - Sht 2 of 3 Single Blower system wiring

Página 52

55 EMS 1101 - Sht 3 of 3 Without Blower system wiring

Página 53 - Blower Performance

5 Filter correction 33 Course adjustments 35 Micro-turn parts list 35 Filter certification 36 SSeeccttiioonn 77 3377 Preventive/corrective main

Página 54

6 WARRANTEE REGISTRATION Read this manual before attempting installation! NOTICE: Information contained in this manual is subject to change

Página 55

7 Customer service We strive to provide efficient and expedient service when an instrument or component is returned for repair. Your assistance c

Página 56

8 CLAIMS FOR DAMAGED SHIPMENTS Inspect all instruments thoroughly on receipt. Check material in the container (s) against the enclosed packing list